    My O gauge sound equipped 33 didn`t have the fan fitted to the chip when it was installed.
    I have installed the wires to AUX1 & +U terminals , this operates on function 19 on my Lenz handset.
    Can anyone tell me how to turn down the fan motor , I have tried CV291 , that had no impact.
    The function menu tells me that had the fan been installed it would have been on number 12 , when I operate that number there is a sound.
    My chip fitter doesn`t give advice.

    Tony.
     
  2. Tony Hubbard

    Tony Hubbard Full Member

    Messages:
    76
    Likes Received:
    68
    Joined:
    Oct 10, 2020
    I found out the answer, CV31-16 + CV32-0 must be checked they are set at that , then CV275-2 + CV278-2 .

    TONY.
     